Solutions Overview
Mobile Operators
Fixed Line Operators
MSO/Cable Operators
Government Networks
Utility Networks
Product Overview
Optical Switching
Edge to Core Optical Switching
SILVX Network Management
Design and Analysis
Network Access
Multiservice Cross-Connects
Multiservice Access Platforms
Access Gateways
ENvision Network Management
DNX-11 Multiservice Cross-Connect
The First Right-Sized, Multiservice DCS
Model Number
- MKT-006-00110: DNX-11 Chassis (Power Supplies Sold Separately)
Mechanical Chassis
- Capacity for up to eleven (11) Application Modules (Up to 88 T1/E1 circuits)
- Midplane Architecture with Front Application Modules and Rear Interface Modules
Equipment Floor Loading
- 226.7 lbs./sq. ft.
Equipment Heat Dissipation (AC)
- 175 Watts, Fully Populated Unit will Generate approx. 27 Watts/sq. ft. Surface Temperatures Measured at 27.6°C
Equipment Heat Dissipation (DC)
- 240 Watts
Switching Capacity
- 262 Mbps Non-blocking TDM buss
Overcurrent Protection
- 15 Amp Circuit Breaker
Dimensions
- 432 mm W x 356 mm D x 267 mm H (17" x 14" x 10.5"); 6 RU height
Weight
- 25 lbs. (empty)
Mounting
- Desktop or Rack Mount (19" or 23")
Power
- MKT-006-11048: DC Input: 48 Vdc ±10%, 6 Amps, 288 Watts (Required for Both Inputs to Support Redundancy) Redundancy Optional
- MKT-006-11206: AC Input: 100 to 240 VAC, 47-63 Hz, 3 Amps, 300 Watts (Required for Both Inputs to Support Redundancy) Redundancy Optional
Environment
- 0° (32°F) to 50°C (122°F) Temperature
- 0% to 90% Humidity (Non-Condensing)
Compliance
- CB Safety Report, CE, CSA, FCC, IC ICES-003, UL1950, NEBS Level 3